Addressable fire detection and extinguishing control panel 1 Loop
Addressable fire detection and extinguishing control panel. The characteristics listed refer to the TSA1 EXTENDED...
Addressable fire detection and extinguishing module for TSA1 control panel.
Addressable fire detection and extinguishing module. Complete management of a decentralized extinguishing channel. Operating mode:...
Management software for Windows 32/64 bit environment.
Management software for Windows 32/64 bit environment. The TFSW-TECNOMONITOR software allows you to monitor and...
Hardware key function interface (dongle) for Tecnofire software.
Hardware key function interface (dongle) for Tecnofire software. Enables TCP/IP software operation. USB cable included.
Programming and remote management software for Windows 32/64 bit environment.
Programming and remote management software for Windows 32/64 bit environment. The software allows you to...
Programming and management software
Programming and management software for Windows 32/64 bit environment. The software allows you to program...
Mounting box for modules series
Mounting box for modules series TFM. Suitable for systems installed in accessible position.
Addressable module equipped with 2 inputs for 4-20mA devices.
Addressable module equipped with 2 inputs for 4-20mA devices, individually identified by the system. Programmable...
Addressable module equipped with 1 Conventional input.
Addressable module equipped with 1 input for conventional detectors. Opto-isolated power supply. Programmable functions: Prealarm...
Addressable module equipped with 5 outputs.
Output connection in contact mode or controlled line. Programming: operating criteria, activation time and delay....
Addressable module with 1 output.
Programming: operating criteria, activation time and delay. Output activation subject to formula. 1 output status...
Addressable module equipped with 2 inputs and 1 output.
Addressable module equipped with 2 inputs and 1 output, individually identified by the system. Inputs:...
Addressable module equipped with 5 inputs.
Addressable module equipped with 5 inputs, individually identified by the system. Inputs connection in Alarm...
Addressable module equipped with 2 inputs.
Addressable module equipped with 2 inputs, individually identified by the system. Inputs connection in Alarm...
Addressable module with 1 input
Addressable module with 1 input. Input connection in Alarm or Fault mode. Programmable operating criteria....
Addressable optical-acoustic warning device - White
Addressable optical-acoustic warning device, for VID fire alarm signal. Sound pressure 102dB(A) @ 1m. Type...
Addressable optical-acoustic warning device
Addressable optical-acoustic warning device, for VID fire alarm signal. Sound pressure 102dB(A) @ 1m. Type...
Adapter for mounting TFCP series.
Pack of 5 frame adaptors per flush box 503 with call points TFCP and TFCPC...
Transparent anti-vandal cover
Transparent anti-vandal cover with anti-opening clamp, for TFCP, TFCP-C and TFCP IP55 series call points....
Addressable resettable call point, for manual fire alarm signaling.
Addressable resettable call point, for manual fire alarm signaling. Manual operation, Type A (direct). Module...
Addressable resettable call point, for manual fire alarm signaling.
Addressable resettable call point, for manual fire alarm signaling. Manual operation, Type A (direct). Module...
Optical repeater.
Optical repeater, red LED. 360° visibility Surface mounting. ABS casing. IP22. White color. Dimensions (L...
Mounting base with Siren
Detector mounting base with integrated acoustic signaling device. The base can be used to host...
Mounting base - Black
Mounting base for detectors and sirens TFIS01, TFIES02. ABS material. Black color. Dimensions (D x...
Mounting base
Mounting base for detectors and sirens TFIS01, TFIES02. ABS material. White color. Dimensions (D x...
Combined detector configurable - Black
Configurable combined detector, can be used with analogue addressed or conventional control panels. The detector...
Optical smoke detector configurable - Black
Optical smoke detection technology Tyndall effect. Configurable optical smoke detector, can be used with analogue...
Thermal smoke detector adressable.
Addressable rate-of-rise detector. Maximum precision in determining the ambient temperature. Programmable functions: thermal Category: A1-58°...
Combined detector configurable
Configurable combined detector, can be used with analogue addressed or conventional control panels. The detector...
Optical smoke detector configurable
Optical smoke detection technology Tyndall effect. Configurable optical smoke detector, can be used with analogue...
Telecommunications interface.
Telecommunications interface reserved for carrying out all control, monitoring and maintenance management activities, of Tecnofire...
IP vector telecommunication device.
IP vector telecommunication device. 8 communicators/channels dedicated to event telematic activities and 6 TCP/IP telecommunication...
Graphics maps software activation.
Implementation of interactive synoptic management of 32 custom graphics maps.
Supported System Commands: Silencing and Control...
Management and control panel.
Management and control repeater panel, equipped with a multifunctional user interface consisting of: 7” TFT...
Fibre optic converter for long-distance.
S485-fibre optic converter for long-distance data transfer of an RS485 line, via a fiber optic...
Table support base
Desktop mounting support for TFT-7C repeater panel.Table stand for TFT-7C repeater panel. The stand offers...
Junction box
Junction box for flush mounting of TFT-7 series repeater panels. The box can be fitted...
Management and control panel - Without Maps
Repeater panel equipped with a multifunctional user interface consisting of: 4.3" TFT capacitive touch screen...
Management and control panel - With Maps
Synoptic management and control repeater panel, with the same *Features* and functionalities as those of...
Addressable fire detection control panel 4 Loop.
4-loops addressable fire alarm panel managing up to 1192 devices via the loops - Proprietary...
Addressable fire detection control panel 2 Loop.
2-loops addressable fire alarm panel managing up to 596 devices via the loops - Proprietary...
Addressable fire detection control panel 1 Loop.
1-loop addressable fire alarm panel managing up to 298 devices via the loop - Proprietary...
Yellow resettable conventional MCP for indoor use,
Yellow resettable conventional MCP for indoor use,
Manual call point ATEX
Conventional manual call point for mounting in outdoors or potentially explosive atmospheres